Default Sample rate weirdness with TI (clicks and pops)

guys

i have a big ben clock kicking out sample rate wordclock to all my devices at 44.1,

ok...also sx3 is > current project is kicking out 44.1 / 24 bit

the ti is sync auto from cubase right (as a VST)...but the ti says it changes the sample rate now to 48 ????wtf ?

i tried to set the ti manual to 44.1 but you cant ...it still gets the clock from host...which is set at 44.1...also my RME is set to 44.1 in and out

where does the ti get 48 from ?????

i get random clicks and pops and want all devices on 44.1

any suggestions

ms
__________________
3xP4 ? CPU 3,20Ghz; 4 Gb RAM; RAID0
3xRME Pro96/8 2.10 + RME WCM 2
Cubase 4.5.2, 3 UAD-1 4.2, 2 x ESI Miditerminal 8U
Yamaha MSP-10 Monitors & O1V96 (v2)
4x19 TFT Screens & Big Ben + Plenty of toys (one of them is the virus TI